In the interest of continuous improvement, an update will be deployed to the Bridges starting July 7, 2025. The main consequence of this update will be to maintain a permanent connection between a Bridge and the Wattsense servers. It will then be possible to push a configuration without activating data reception. The other changes that this update brings are described in this article.
Bridge with Ethernet connection + SIM card (*)
| Function | Now | After the changes |
| Push a configuration to the Box | Data uplink MUST be activated | NO data uplink activation required |
| See properties values in the console | Data uplink MUST be activated | no changes |
| Redirection to a gateway (MQTT, Modbus, BACnet) |
|
Data always go through internet |
| Access to the Box from the Wattsense servers |
|
Permanent connection |
| Logs / events |
Data uplink MUST be activated Send all queued events |
|
| Time interval between two readings |
|
no changes |
| Status and colors |
|
no changes |
Bridge without Ethernet connection (only SIM card)
| Function | Now | After the changes |
| Push a configuration to the Box | Data uplink MUST be activated | NO data uplink activation required |
| See properties values in the console | Data uplink MUST be activated | no changes |
| Redirection to a gateway (MQTT, Modbus, BACnet) | The data are redirected only when the data uplink is activated | Not supported (no redirection) |
| Access to the Box from the Wattsense servers |
|
Permanent connection |
| Logs / events |
|
|
| Time interval between two readings |
|
no changes |
| Status and color |
|
|
(*) if the cellular connection is not strong enough to communicate with the Wattsense servers (meaning that the box can't get an IP address through the cellular connection), the ethernet connection, when available, is used. When both are available, the cellular connection will have the priority.
Tower with Ethernet connection + SIM card
As a reminder and for information, the same grid for the Tower
| Function | Now | After the changes |
| Push a configuration to the Box | / | / |
| See properties values in the console | / | / |
| Redirection to a gateway (MQTT, Modbus, BACnet) |
|
no changes |
| Access to the Box from the Wattsense servers | / | / |
| Logs / events | / | / |
| Time interval between two readings |
|
no changes |
| Status and colors | / | / |
Tower without ethernet connection (only SIM card)
| Function | Now | After the changes |
| Push a configuration to the Box | / | / |
| See properties values in the console | / | / |
| Redirection to a gateway (MQTT, Modbus, BACnet) | via the cellular connection | no changes |
| Access to the Box from the Wattsense servers | / | / |
| Logs / events | / | / |
| Time interval between two readings |
|
no changes |
| Status and colors | / | / |
Please contact us if you need any additional information : Wattsense Support
Comments
0 comments
Article is closed for comments.